Temporary Power

Understanding your temporary power distribution needs

IDE has over 25 years' experience in designing power distribution solutions. With direct access to our skilled engineers, we can help you understand and specify solutions for any event.

Optimising your temporary power distribution network

IDE supplies a full range of temporary power distribution panels from 4000A generator connections to small dual 16A sockets, and all connecting cable to ensure you optimise your temporary power network. We fit the product to the application.

Quality and safety assured

Every time any of our products leave our rental depot or manufacturing base, we test operation and safety. This includes EVERY socket, EVERY breaker, EVERY cable connection to ensure the highest reliability.

Long-term partnership

We can help you plan ahead, ensuring you get the best from your temporary power distribution set-up and our expert services. We can also manage your complete distribution fleet, or provide one stop rental management.

The automatic changeover panel is a quick and easy solution designed to divert power from your main on-site generator to the back-up generator in the event of a power failure. Our automatic changeover panels are easy to relocate across site and are housed in high density polyethylene enclosures, which are fitted in a stainless steel crash frame to combat against harsh weather conditions.  We offer a high quality automatic changeover solutions ranging from 630A-4000A available to purchase or hire. Not sure what you're looking for? Speak to our team of trusted advisors who are on-hand to make sure that you find the right solution for your project.

  • AMF 800S-1

    Three-phase auto mains fail (AMF) unit allows automatic connection of a secondary electrical supply to a load upon…

    Three-phase auto mains fail (AMF) unit allows automatic connection of a secondary electrical supply to a load upon failure of the primary. Mechanically and electronically interlocked 4 Pole AC1 rated contactors supplying a common rated HDHC copper busbar system and load connection pads. No volt connection for remote Generator start (N/O & N/C). Auxiliary power supply for Generator battery charging/jacket water heater. 3 Position key switch for Auto, Test and Generator run. Supply availability neon’s for visual representation of status. Incoming supply adjustable undervolt and time delay relays for setting of individual supply parameters. All equipment housed in a steel enclosure with internal and external brass earth bar. Complete unit mounted within a galvanised steel crash frame with forklift pockets and lifting eyes.

    Enclosure
    Grey (RAL7035) textured powder coated Zintec steel construction with phosphate welds. Separate incoming and outgoing (with control gear) compartments with internal protection shrouds and external panel key lock doors. Aluminium gland plate. Assembled to IP55.

    Input 1 (Mains): Termination, 3P+N+E Hardwire Protection, 800A 4 Pole Contactor

    Input 2 (Generator): Termination, 3P+N+E Hardwire Protection, 800A 4 Pole Contactor

    Outgoing (Load): Termination, 3P+N+E Hardwire Protection, N/A

    Aux 32A 230V 1P+N+E Socket 32A 2 Pole 30mA RCBO (All MCB’s have C-Type trip curves. All RCD’s and RCBO’s are Type A)

    Dimensions: H 1800mm x W 1260mm x D 600mm

    Weight: 320kg

  • AMF400S-1

    Three-phase auto mains fail (AMF) unit allows automatic connection of a secondary electrical supply to a load upon…

    400A Chnagover Panel

    Three-phase auto mains fail (AMF) unit allows automatic connection of a secondary electrical supply to a load upon failure of the primary. Mechanically and electronically interlocked 4 Pole AC1 rated contactors supplying a common rated HDHC copper busbar system and load connection pads. No volt connection for remote Generator start (N/O & N/C). Auxiliary power supply for Generator battery charging/jacket water heater. 3 Position key switch for Auto, Test and Generator run. Supply availability neon’s for visual representation of status. Incoming supply adjustable undervolt and time delay relays for setting of individual supply parameters. All equipment housed in a steel enclosure with internal and external brass earth bar. Complete unit mounted within a galvanised steel crash frame with forklift pockets.

    Enclosure

    Grey (RAL7035) textured powder coated Zintec steel construction with phosphate welds. Separate incoming and outgoing (with control gear) compartments with internal protection shrouds and external panel key lock doors. Aluminium gland plate. Assembled to IP55.

    • Input 1 (Mains): 3P + N + E (Hardwire) . Protection: 400A 4 Pole Contactor
    • Input 2 (Generator): 3P + N + E (Hardwire) . Protection: 400A 4 Pole Contactor
    • Outgoing Load: 3P + N + E (Hardwire) . Protection: N/A
    • Aux: 32A 230V 1P+N+E socket. Protection: 32A 2 Pole 30mA RCBO
    • Dimensions: H1700 x W985 x D530 (mm)
    • Weight – 206kg

    All temporary power distribution equipment is manufactured by IDE in the UK and tested to BS 7671 (12 Months Certification). The products used within our distribution systems conform to EN 60309, EN 60529, EN 60947 and have a 12 month warranty.

    This 400A Changeover Panel  is available to purchase or hire. For more information, please contact [email protected]

Not found what you are looking for? Fill in the form below and one of our IDE Advisors will contact you, to go through your requirement in more detail.

  • One of our friendly team members will get back to you

Your quote list
Your quote list is empty.