Temporary Power
Understanding your temporary power distribution needs
IDE has over 25 years' experience in designing power distribution solutions. With direct access to our skilled engineers, we can help you understand and specify solutions for any event.
Optimising your temporary power distribution network
IDE supplies a full range of temporary power distribution panels from 4000A generator connections to small dual 16A sockets, and all connecting cable to ensure you optimise your temporary power network. We fit the product to the application.
Quality and safety assured
Every time any of our products leave our rental depot or manufacturing base, we test operation and safety. This includes EVERY socket, EVERY breaker, EVERY cable connection to ensure the highest reliability.
Long-term partnership
We can help you plan ahead, ensuring you get the best from your temporary power distribution set-up and our expert services. We can also manage your complete distribution fleet, or provide one stop rental management.
Site Power Distribution
Our site power distribution equipment is designed to withstand the tough conditions of construction sites and is used to supply temporary power to site cabins, heaters, lighting, tools and plant equipment. We offer a range of temporary power solutions such as: site power distribution boards, cabling solutions and site transformers. All of our site power equipment is available for hire or purchase, supporting both short term and long term projects.
If you can't find the solution that you are looking for, give us a call - our team of trusted advisors are on-hand to help you find the right solution for your project.
-
SD63
Three-phase mains distribution unit for use on any temporary electrical installation or construction site. Equipment…
Three-phase mains distribution unit for use on any temporary electrical installation or construction site. Equipment housed in a 1.4003 (3CR12) stainless steel enclosure designed to IP55 with textured powder coat finish to RAL 7021 – dark grey. (Other colours are available by request).
Main door to gain access to final distribution circuits, secondary door for access to main switch only. Main door provided with a pad lock facility.
Bottom entry 3mm aluminum gland plate, top mounted rain cover, and pre-punched sides for outgoing socket mounting from 16A to 63A, IP44 and IP67.
Enclosure mounted within a galvanized box section crash frame complete with fork lift pockets.Incomer: 63A 3 Phase in
Outgoing: 1 x 63a/1
Outgoing: 8 x 32a/1
Outgoing: 1 x 16a/1
-
SD160
Three-phase mains distribution unit for use on any temporary electrical installation or construction site. Equipment…
Three-phase mains distribution unit for use on any temporary electrical installation or construction site. Equipment housed in a 1.4003 (3CR12) stainless steel enclosure designed to IP55 with textured powder coat finish to RAL 7021 – dark grey. (Other colours are available by request). Main door to gain access to final distribution circuits, secondary door for access to main switch only. Main door provided with a pad lock facility. Bottom entry 3mm aluminum gland plate, top mounted rain cover, and pre-punched sides for outgoing socket mounting from 16A to 63A, IP44 and IP67.
Enclosure mounted within a galvanized box section crash frame complete with fork lift pockets.
Incomer: 160A 3Phase In
Outgoing: 6 x 63a/1
Outgoing: 1 x 32a/3
Outgoing: 2 x 32a/1
Outgoing: 2 x 16a/1
-
ST203
Robust heavy duty metal case conforming to IP44 with two carry handles and mounted on skids. Finished in red and yellow.…
Robust heavy duty metal case conforming to IP44 with two carry handles and mounted on skids. Finished in red and yellow.
Transformer:
> 20.0 kVA continuous rated isolating transformer,
> Primary 400 volts 3 Phase 50 / 60 Hz.
> Protected by a 32A 3 Pole MCB.
> Fitted with 2 meters of SY Flying Lead and a 63A 5 Pin CeeForm Plug.Secondary – Sockets:
> 8 x 110 volt 16 amp 2P + E – IP44 outlets.
> Protected in pairs by 16A 2 Pole MCB’s.
> 4 x 110 volt 32 amp 2P + E – IP44 outlets.
> Protected individually by 32A 2 Pole MCB’s.Dimensions : H: 910mm x W: 660mm x D: 630mm
Weight: 140 Kgs
-
AMF125S-1
Three-phase auto mains fail (AMF) unit allows automatic connection of a secondary electrical supply to a load upon…
Three-phase auto mains fail (AMF) unit allows automatic connection of a secondary electrical supply to a load upon failure of the primary. Mechanically and electronically interlocked 4 Pole AC1 rated contactors. No volt connection for remote Generator start (N/O & N/C). Auxiliary power supply for Generator battery charging or jacket water heater. 3 Position key switch for Auto, Test and Generator run. Supply availability neon’s for visual representation of status. Incoming supply adjustable undervolt and time delay relays for setting of
individual supply parameters. All equipment housed in a steel enclosure with external brass earth stud. Complete unit
mounted within a galvanised steel crash frame with forklift pockets.Enclosure
Grey (RAL7035) textured powder coated Zintec steel construction with phosphate welds. Termination compartment with internal polycarbonate/terminal protection shrouds and external panel key lock door. Top and bottom steel gland plate. Assembled to IP55.Termination Protection
Input 1 (Mains): Termination, 3P+N+E Hardwire Protection, 125A 4 Pole Contactor
Input 2 (Generator): Termination, 3P+N+E Hardwire Protection, 125A 4 Pole Contactor
Outgoing (Load): Termination, 3P+N+E Hardwire Protection, N/A
Aux 13A 230V 1P+N+E Socket 16A 2 Pole 30mA RCBO (All MCB’s have C-Type trip curves. All RCD’s and RCBO’s are Type A)Dimensions: H 1400mm x W 985mm x D 500mm
Weight: 75kgs
-
AMF 250s-1
Three-phase auto mains fail (AMF) unit allows automatic connection of a secondary electrical supply to a load upon…
Three-phase auto mains fail (AMF) unit allows automatic connection of a secondary electrical supply to a load upon failure of the primary. Mechanically and electronically interlocked 4 Pole AC1 rated contactors supplying a common rated HDHC copper busbar system and load connection pads. No volt connection for remote Generator start (N/O & N/C). Auxiliary power supply for Generator battery charging/jacket water heater. 3 Position key switch for Auto, Test and Generator run. Supply availability neon’s for visual representation of status. Incoming supply adjustable undervolt and time delay relays for setting of individual supply parameters. All equipment housed in a steel enclosure with internal and external brass earth bar. Complete unit mounted within a galvanised steel crash frame with forklift pockets.
Enclosure
Grey (RAL7035) textured powder coated Zintec steel construction with phosphate welds. Separate incoming and outgoing (with control gear) compartments with internal protection shrouds and external panel key lock doors. Aluminium gland plate. Assembled to IP55.Specification
Input: Termination, 3P+N+E Hardwire Protection, 250A 4 Pole Contactor
Input 2 (Generator): Termination, 3P+N+E Hardwire Protection, 250A 4 Pole Contactor
Outgoing (Load): Termination, 3P+N+E Hardwire Protection, N/A
Size: H 1700mm x W 985mm x D 530mm
Weight: 160kgs
-
AMF 800S-1
Three-phase auto mains fail (AMF) unit allows automatic connection of a secondary electrical supply to a load upon…
Three-phase auto mains fail (AMF) unit allows automatic connection of a secondary electrical supply to a load upon failure of the primary. Mechanically and electronically interlocked 4 Pole AC1 rated contactors supplying a common rated HDHC copper busbar system and load connection pads. No volt connection for remote Generator start (N/O & N/C). Auxiliary power supply for Generator battery charging/jacket water heater. 3 Position key switch for Auto, Test and Generator run. Supply availability neon’s for visual representation of status. Incoming supply adjustable undervolt and time delay relays for setting of individual supply parameters. All equipment housed in a steel enclosure with internal and external brass earth bar. Complete unit mounted within a galvanised steel crash frame with forklift pockets and lifting eyes.
Enclosure
Grey (RAL7035) textured powder coated Zintec steel construction with phosphate welds. Separate incoming and outgoing (with control gear) compartments with internal protection shrouds and external panel key lock doors. Aluminium gland plate. Assembled to IP55.Input 1 (Mains): Termination, 3P+N+E Hardwire Protection, 800A 4 Pole Contactor
Input 2 (Generator): Termination, 3P+N+E Hardwire Protection, 800A 4 Pole Contactor
Outgoing (Load): Termination, 3P+N+E Hardwire Protection, N/A
Aux 32A 230V 1P+N+E Socket 32A 2 Pole 30mA RCBO (All MCB’s have C-Type trip curves. All RCD’s and RCBO’s are Type A)
Dimensions: H 1800mm x W 1260mm x D 600mm
Weight: 320kg
-
SD250
Three-phase mains distribution unit for use on any temporary electrical installation or construction site. Equipment…
Three-phase mains distribution unit for use on any temporary electrical installation or construction site. Equipment housed in a 1.4003 (3CR12) stainless steel enclosure designed to IP55 with textured powder coat finish to RAL 7021 – dark grey. (Other colours are available by request).
Main door to gain access to final distribution circuits, secondary door for access to main switch only. Main door provided with a pad lock facility.
Bottom entry 3mm aluminum gland plate, top mounted rain cover, and pre-punched sides for outgoing socket mounting from 16A to 63A, IP44 and IP67.
Enclosure mounted within a galvanized box section crash frame complete with fork lift pockets.Incomer: 250A 3Phase In
Outgoing: 2 x 63a/3
Outgoing: 2 x 63a/1
Outgoing: 2 x 32a/3
Outgoing: 10 x 32a/1
Outgoing: 1 x 16a/3
Outgoing: 2 x 16a/1
-
SD125
125A site distribution board designed to make connection from the temporary generator to on-site equipment such as…
125A site distribution board designed to make connection from the temporary generator to on-site equipment such as tools, lighting, heaters, plant machinery and cabins. Our site distribution boards are kept on standby at our three strategically placed locations across the UK, so we can deliver them to you quickly. 125A site distribution boards can be custom built to suit the needs of your project. Available to purchase or hire.
Product details
The site distribution board is housed in a 1.4003 stainless steel enclosure, designed to IP55 with a textured powder coat finish to RAL 7021 – dark grey. The site distribution board features two doors – the main door, which allows the user access to the final distribution circuits and has a padlock facility which is designed as an additional safety feature. The second door allows the user access to the mains switch only.
The 125A site distribution board has a bottom entry 3mm aluminium gland plate, top mounted rain cover, and pre-punched sides to allow for socket mounting (16A, 32A & 63A – IP44 & IP67). The enclosure is mounted within a galvanized box section floor stand which can be easily relocated across site.
The equipment has an incoming 4 pole thermal magnetic strip and optional adjustable/switchable incoming earth leakage can be added if required. The 4 pole busbar distribution system allows an easy connection for 2 pole and 4 pole outgoing devices such as RCD’s and RCBO’s. The internal earth bar is bonded to external studs on enclosure and frame. The equipment has an incoming 125A IP67 flying lead to allow for connection to a temporary generator.
Options
- 230V – 400V single and three phase – 50hz
- Interchangeable socket outlets from 16A – 63A
- both IP44 or IP67 available
- Glanded hardwire facility
- MCB’S have C – type trip curves, all RCD’s and RCBO’s are type A
- IP rating: IP54 up to IP65
- Stainless steel 1.4003 or Zintec 2.00 mm enclosures available
- Door interlocking pad lockable handle
- Secondary door for access to main supply for safe isolation
- Galvanised crash frame, forklift pockets and certifi d lifting points
- Optional switchable and adjustable earth leakage
- External earth stud on crash frame and enclosure
- RAL colours available upon request
- 1
- 2
Not found what you are looking for? Fill in the form below and one of our IDE Advisors will contact you, to go through your requirement in more detail.