Contingency Power
Understanding your contingency power connection needs
IDE has over 25 years' experience in designing power distribution solutions. With direct access to our skilled engineers, we can help you understand and specify solutions for generator connection.
Highest reliability components and switchgear
You need to know that, when it's needed, the contingency power can be relied upon. We use the highest quality switchgear in all our products, giving you confidence.
Site survey and installation
We provide site surveys to advise on positioning and power connection and switching requirements, and can also install if required.
Long term partnership
We innovate to suit the needs of our customers and can create bespoke products and services to match your capital and operational budgets.
We specialise in designing solutions that allow a quick connection to a back-up power source in the event of power failure or emergency shutdown. We can also supply temporary overlays when maintenance work is carried out on your facility’s existing switchgear.
-
240mm Cable (Powerlock)
240mm single-core HO7RN-F cable terminated with powerlock ends (source and drain) or lugged ends to make connections…
240mm single-core HO7RN-F cable terminated with powerlock ends (source and drain) or lugged ends to make connections to standby or permanent generators.
Sizes available:
> 5 Metres
> 10 Metres
> 15 Metres
> 20 Metres
> 25 Metres
> 50 Metres
All of our 240mm cable solutions are available for purchase or hire and can be turned around quickly to support your project.
Approx weight per metre (5 wire set – L1, L2, L3, Earth and Neutral): 15kg
-
LBC2000
2000A three-phase, neutral and earth Load Bank Connection designed to restore power to critical applications. The 3200A…
2000A three-phase, neutral and earth Load Bank Connection designed to restore power to critical applications. The 3200A Generator Connection Point can be fitted inside or outside of a building, allowing a safe and quick connection of load bank to your generator when required.
Equipment housed within a steel enclosure. Powerlock (Drain) connections to 100x10mm copper bars with 300mm spreading distance for bottom entry outgoing cables. 3mm aluminium top and bottom gland plates are provided for the customer
Enclosure
Dark Grey (RAL7021) textured powder coated stainless steel construction (1.4003 grade). Other colour options maybe available by request. Powerlocks mounted on a 45 degree angle aluminum plate. 3mm aluminum top and bottom gland plates are provided. Assembled to IP54.
Specification
- Incomer: 3P + N + E 500A Powerlock Drain . Protection: N/A
- Outgoing: 10 x 10 copper bars c/w M12 clearance holes. Protection: N/A
- Dimensions: H18350 x W950 x D360 (mm)
- Weight – 150kg
Operation
We recommend the generator should be connected / disconnected when off load and not running. No voltage should be present at the powerlocks. We would also recommend following the convention of connecting in the following order: Earth – Neutral – L1 – L2 – L3. Then disconnecting in the reverse order.
All temporary power distribution equipment is manufactured by IDE in the UK and tested to BS 7671 (12 Months Certification). The products used within our distribution systems conform to EN 60309, EN 60529, EN 60947 and have a 12 month warranty.
-
Mobility Access Cable Ramp
IDE’s 5 channel cable ramps are manufactured from UV stabilised and halogen free polyurethane. 100% Non-Conductive…
IDE’s 5 channel cable ramps are manufactured from UV stabilised and halogen free polyurethane. 100% Non-Conductive cable ramps. Highly Visible Red (RAL3020) and Black colour combination with unique tread pattern providing increase grip on side ramps. Designed for mobility access.
Dimensions: H35mmx W1050mm x D920mm
Maximum load: 4763kg
-
150mm Cable (Lugg Ends)
150mm single-core HO7RN-F cable terminated with lugged ends (M12 standard) to make connections to standby or…
150mm single-core HO7RN-F cable terminated with lugged ends (M12 standard) to make connections to standby or permanent generators.
Available with powerlock source/drain terminations if required.
Sizes available:
> 5 Metres
> 10 Metres
> 15 Metres
> 20 Metres
> 25 Metres
> 50 Metres
All of our 240mm HO7RN-F cable solutions are available for purchase or hire and can be turned around quickly to support your project.
Approx weight per metre (5 wire set – L1, L2, L3, Earth and Neutral): 15kg
-
16A Single Phase Cable
16A single phase cable is designed to connect the temporary power network from the generator directly to the end user.…
16A single phase cable is designed to connect the temporary power network from the generator directly to the end user.
The 16A single phase (400V) extension lead is fitted with a 16A 5 pin IP44 Mennekes plug and coupler at each end.
Sizes available:
> 5 Metres
> 10 Metres
> 15 Metres
> 20 Metres
> 25 Metres
> 50 Metres
The cable used is 2.5mm 5core H07RN-F Double insulated, Ethylene Propylene Rubber, flexible cable designed to withstand; the weather, oils/greases, mechanical and thermal stresses. Conforms to BS EN 7919.
Approximate weight per metre – 0.215kg
All cable is available to purchase or hire and can be made up in lengths ranging from 1-100M.
16A single phase cable can be terminated with IP67 plugs and couplers if required.
-
AMF125S-1
Three-phase auto mains fail (AMF) unit allows automatic connection of a secondary electrical supply to a load upon…
Three-phase auto mains fail (AMF) unit allows automatic connection of a secondary electrical supply to a load upon failure of the primary. Mechanically and electronically interlocked 4 Pole AC1 rated contactors. No volt connection for remote Generator start (N/O & N/C). Auxiliary power supply for Generator battery charging or jacket water heater. 3 Position key switch for Auto, Test and Generator run. Supply availability neon’s for visual representation of status. Incoming supply adjustable undervolt and time delay relays for setting of
individual supply parameters. All equipment housed in a steel enclosure with external brass earth stud. Complete unit
mounted within a galvanised steel crash frame with forklift pockets.Enclosure
Grey (RAL7035) textured powder coated Zintec steel construction with phosphate welds. Termination compartment with internal polycarbonate/terminal protection shrouds and external panel key lock door. Top and bottom steel gland plate. Assembled to IP55.Termination Protection
Input 1 (Mains): Termination, 3P+N+E Hardwire Protection, 125A 4 Pole Contactor
Input 2 (Generator): Termination, 3P+N+E Hardwire Protection, 125A 4 Pole Contactor
Outgoing (Load): Termination, 3P+N+E Hardwire Protection, N/A
Aux 13A 230V 1P+N+E Socket 16A 2 Pole 30mA RCBO (All MCB’s have C-Type trip curves. All RCD’s and RCBO’s are Type A)Dimensions: H 1400mm x W 985mm x D 500mm
Weight: 75kgs
-
GCP630(Lock off connections)
630A three-phase, neutral and earth Generator Hookup Point designed to restore power to critical applications. The…
630A three-phase, neutral and earth Generator Hookup Point designed to restore power to critical applications. The Generator Hookup Point can be fitted inside or outside of a building, allowing a safe and quick connection of a back-up generator to your facility’s electrical system when required. The equipment is housed within a wall mounted steel enclosure. Powerlock (Drain) connections to copper bars allow for top entry outgoing cables. 3mm aluminium top and bottom gland plates are provided for the customer. Powerlock (Source) cables can be supplied by IDE at an additional cost. Once connections have been made, the powerlocks can then be locked off to avoid further interference.
Enclosure
High vis orange (RAL7021) textured powder coated stainless steel construction (1.4003 grade). Other colour options maybe available by request. Powerlocks mounted on a 45 degree angle aluminum plate. 3mm aluminium top and bottom gland plates are provided. Assembled to IP54. Other enclosures – such as mild steel can be supplied upon request.
Specification
- Incomer: 3P + N + E Powerlock Drain . Protection: N/A
- Outgoing: 3 x 10 copper bars c/w M12 clearance holes. Protection: N/A
- Dimensions: H750 x W500 x D250 (mm)
- Weight – 35kg
This product is available as a standalone solution, or can be installed by our team of engineers once they have conducted a site survey of your premises.
All temporary power distribution equipment is manufactured by IDE in the UK and tested to BS 7671 (12 Months Certification). The products used within our distribution systems conform to EN 60309, EN 60529, EN 60947 and have a 12 month warranty.
-
GCP 630Se-1
The Generator Connection Point (GCP) is designed to restore power to critical applications such as hospitals, schools,…
The Generator Connection Point (GCP) is designed to restore power to critical applications such as hospitals, schools, airports, banks and other commercial facilities. They can be fitted inside or outside of a building, allowing a safe and quick connection of a-back up generator to your facility’s electrical system when required. The solutions can also be used to connect to your load bank when your back-up generator is undergoing testing/maintenance.
GCP630A
630A three-phase, neutral and earth Generator Connection Point designed to connect to a temporary generator (generator supplied by others). Equipment housed within a wall mounted steel enclosure. Powerlock (Drain) connections to copper bars allow for top entry outgoing cables. 3mm aluminium top and bottom gland plates are provided for the customer. Power lock (source) cables can be supplied at an extra cost to make connection to the Generator Connection Point.
Enclosure
Dark Grey (RAL7021) textured powder coated stainless steel construction (1.4003 grade). Other colour options maybe available by request. Powerlocks mounted on a 45 degree angle aluminum plate. 3mm aluminium top and bottom gland plates are provided. Assembled to IP54. Other enclosure options – such as mild steel, are available upon request.
Specification
- Incomer: 3P + N + E Powerlock (Drain). Protection: N/A
- Outgoing: Fully rated copper, capable to suit 2 x M12 connections. Protection: N/A
- Dimensions: H400 x W400 x D280 (mm)
- Weight – 24kg
Operation
We recommend that the generator should be connected/disconnected when off load and not running. No voltage should be present at the power locks. We recommend following the convention of connecting in the following order: Earth – Neutral – L1 – L2 – L3, then disconnecting in reverse order.
All temporary power distribution equipment is manufactured by IDE in the UK and tested to BS 7671 (12 Months Certification). The products used within our distribution systems conform to EN 60309, EN 60529, EN 60947 and have a 12 month warranty.
For more information on our Generator Connection Points please contact sales@idesystems.co.uk.
-
GCP 1000Se-1
The Generator Connection Box is designed to restore power to critical applications such as hospitals, schools, airports,…
The Generator Connection Box is designed to restore power to critical applications such as hospitals, schools, airports, banks and other commercial facilities. They can be fitted inside or outside of a building, allowing a safe and quick connection of a-back up generator to your facility’s electrical system when required. The solutions can also be used to connect to your load bank when your back-up generator is undergoing testing/maintenance.
GCP 1000Se-1
1000A three-phase, neutral and earth Generator Connection Box designed to connect to a temporary generator (generator supplied by others). Equipment housed within a wall mounted steel enclosure. Powerlock (Drain) connections to copper bars allow for top entry outgoing cables. 3mm aluminium top and bottom gland plates are provided for the customer. Power lock (source) cables can be supplied at an extra cost to make connection to the Generator Connection Box.
Enclosure
Dark Grey (RAL7021) textured powder coated stainless steel construction (1.4003 grade). Other colour options maybe available by request. Powerlocks mounted on a 45 degree angle aluminum plate. 3mm aluminium top and bottom gland plates are provided. Assembled to IP54. Other enclosure options – such as mild steel, are available upon request.
Specification
- Incomer: 3P + N + E Powerlock (Drain). Protection: N/A
- Outgoing: Fully rated copper, capable to suit 2 x M12 connections. Protection: N/A
- Dimensions: H400 x W400 x D280 (mm)
- Weight – 24kg
Operation
We recommend that the generator should be connected/disconnected when off load and not running. No voltage should be present at the power locks. We recommend following the convention of connecting in the following order: Earth – Neutral – L1 – L2 – L3, then disconnecting in reverse order.
All temporary power distribution equipment is manufactured by IDE in the UK and tested to BS 7671 (12 Months Certification). The products used within our distribution systems conform to EN 60309, EN 60529, EN 60947 and have a 12 month warranty.
For more information on our Generator Connection Boxes please contact sales@idesystems.co.uk.
Not found what you are looking for? Fill in the form below and one of our IDE Advisors will contact you, to go through your requirement in more detail.